Lookup Part! - 29AH16
|
Solenoid Valve for Extreme Low Ambient Option. SOLENOID VALVE,NORMALLY CLOSED,SOLDER 3/8"ODF
|
|
|
Lookup Part! - 2CKE7-MPU
|
Pipe Insulation. 3/8" ID, 1-1/8" OD, 6 Ft. Long. 3/8" thick. Seam-Seal Split. Used for 3/8" Refrigeration Copper Tubing. R2.5
|
|
|
Lookup Part! - 2CKE7-MPU-INCH
|
Pipe Insulation. 3/8" ID, 1-1/8" OD, 1 In. Long. 3/8" thick. Seam-Seal Split. Used for 3/8" Refrigeration Copper Tubing. R2.5
|
|
|
Lookup Part! - 2CKE8-MPU
|
Pipe Insulation. 1/2" ID, 1-1/4" OD, 6 Ft. Long. 3/8" thick. Seam-Seal Split. Used for 1/2" Refrigeration Copper Tubing. R2.3
|
|
|
Lookup Part! - 2CKE8-MPU-INCH
|
Pipe Insulation. 1/2" ID, 1-1/4" OD, 1 In. Long. 3/8" thick. Seam-Seal Split. Used for 1/2" Refrigeration Copper Tubing. R2.3
|
|
|
Lookup Part! - 2CKE9-MPU
|
Pipe Insulation. 5/8" ID, 1-3/8" OD, 6 Ft. Long. 3/8" thick. Seam-Seal Split. Used for 5/8" Refrigeration Copper Tubing. R2.2
|
|
|
Lookup Part! - 2CKE9-MPU-INCH
|
Pipe Insulation. 5/8" ID, 1-3/8" OD, 1 IN. Long. 3/8" thick. Seam-Seal Split. Used for 5/8" Refrigeration Copper Tubing. R2.2
|
|
|
Lookup Part! - 2CKF1-MPU
|
Pipe Insulation. 3/4" ID, 1-1/2" OD, 6 Ft. Long. 3/8" thick. Seam-Seal Split. Used for 3/4" Refrigeration Copper Tubing. R2.1
|
|
|
Lookup Part! - 2CKF1-MPU-INCH
|
Pipe Insulation. 3/4" ID, 1-1/2" OD, 1 IN Long. 3/8" thick. Seam-Seal Split. Used for 3/4" Refrigeration Copper Tubing. R2.1
|
|
|
Lookup Part! - 2CKF2-MPU
|
Pipe Insulation. 7/8" ID, 1-5/8" OD, 6 Ft. Long. 3/8" thick. Seam-Seal Split. Used for 7/8" Refrigeration Copper Tubing. R2.0
|
|
|
Lookup Part! - 2CKF2-MPU-INCH
|
Pipe Insulation. 7/8" ID, 1-5/8" OD, 1 IN. Long. 3/8" thick. Seam-Seal Split. Used for 7/8" Refrigeration Copper Tubing. R2.0.
|
|
|
Lookup Part! - 2LKJ2-INCH-MPU
|
3/8 In ACR Copper Tubing. 1 in Length. Inside Diameter = .315, Outside Diameter = .375. Max Pressure = 984 PSI, 400 F Max. ASTMB280
|
|
|
Lookup Part! - 2LKJ2-MPU
|
3/8 In ACR Copper Tubing. 50 Feet in Length. Inside Diameter = .315, Outside Diameter = .375. Max Pressure = 984 PSI, 400 F Max. ASTMB280
|
|
|
|
Lookup Part! - 2LKJ3-MPU
|
1/2 In ACR Copper Tubing. 50 Feet in Length. Inside Diameter = .430, Outside Diameter = .500. Max Pressure = 727 PSI, 400 F Max. ASTMB280
|
|
|
Lookup Part! - 2LKJ4-MPU
|
5/8 In ACR Copper Tubing. 50 Feet in Length. Inside Diameter = .545, Outside Diameter = .625. Max Pressure = 618 PSI, 400 F Max. ASTMB280
|
|
|
Lookup Part! - 2LKJ4-MPU-INCH
|
5/8 In ACR Copper Tubing. 1in Length. Inside Diameter = .545, Outside Diameter = .625. Max Pressure = 618 PSI, 400 F Max. ASTMB280
|
|
|
Lookup Part! - 2LKJ5-INCH-MPU/RTU
|
3/4 In ACR Copper Tubing. 1 in Length. Inside Diameter = .666, Outside Diameter = .750. Max Pressure = 511 PSI, 400 F Max. ASTMB280
|
|
|
Lookup Part! - 2LKJ5-MPU
|
3/4 In ACR Copper Tubing. 50 Feet in Length. Inside Diameter = .666, Outside Diameter = .750. Max Pressure = 511 PSI, 400 F Max. ASTMB280
|
|
|
|
Lookup Part! - 2LKJ6-MPU
|
7/8 In ACR Copper Tubing. 50 Feet in Length. Inside Diameter = .785, Outside Diameter = .875. Max Pressure = 495 PSI, 400 F Max. ASTMB280
|
|
|
|
|
|
|
|
|
|
|
Lookup Part! - 4E924
|
Sight Glass with Moisture Indicator for Liquid Line. Sporlan 6 Digit 700299. 1/2" Sweat. Used on DXM 1-4 (2 needed), DXM 2-3 (2 needed), DXM 2-4 (2 needed), DXM 3-2 (2 needed), DXM 3-3 (2 needed), DXM 4-1 (2 needed)
|
|
|
Lookup Part! - 4E927
|
Sight Glass with Moisture Indicator for Liquid Line. Sporlan# 700416 5/8" Sweat. Used on DXM 3-4 (2 needed), DXM 4-2 (2 needed), DXM 4-3 (2 needed), DXM 5-1 (2 needed).
|
|
|
Lookup Part! - 4E928
|
Sight Glass with Moisture Indicator for Liquid Line. Sporlan 6 Digit# 700507
7/8" Sweat. U Ssed on DXM 4-4 (2 needed), DXM 5-2 (2 needed), DXM 5-3 (2 needed)., Sporlan 6 Digit# 700507
|
|
|
Lookup Part! - 4E938
|
Filter Dryer for Liquid Line. 7/8" Sweat. 25 Tons Max. Sporlan 6 Digit# 401837 Used on DXM 4-4 (2 needed), DXM 5-2 (2 needed), DXM 5-3 (2 needed).
|
|
|
|
|
|
Lookup Part! - 5BA93
|
Solenoid Valve for MPU-LBP. SOLENOID VALVE,2WAY,NORMALLY CLOSED,SOLDER 3/8"ODF E5S130-HP
|
|
|
|
Lookup Part! - 63595K31
|
Grommet for .125 dia pipe, Inside diameter = .35", Panel Hole size = 1.0625. Used for 3/8" refrigeration piping.
|
|
|
Lookup Part! - 6X583
|
Filter Dryer for Liquid Lines. 5 Ton Max. Used on MPU. 3/8" Solder connections. 1 Filter Drier required for each condensing unit. (6X583)
Used on DXM 1-1 (1 needed), DXM 1-2 (1 needed), DXM 1-3 (2 needed), DXM 2-1 (2 needed) DXM 2-2 (2 needed), DXM 3-1 (2 needed).
|
|
|
Lookup Part! - 6X586
|
Filter Dryer for Liquid Line. 1/2" Sweat. 10 Ton Max. Sporlan 6 digit # 401023 Used on DXM 1-4 (2 needed), DXM 2-3 (2 needed), DXM 2-4 (2 needed), DXM 3-2 (2 needed), DXM 3-3 (2 needed), DXM 4-1 (2 needed)
|
|
|
Lookup Part! - 6X589
|
Filter Dryer for Liquid Line. 5/8" Sweat. 15 Tons Max. Sporlan# 401449 Used on DXM 3-4 (2 needed), DXM 4-2 (2 needed), DXM 4-3 (2 needed), DXM 5-1 (2 needed)
|
|
|
Lookup Part! - 6X723
|
Sight Glass with Moisture Indicator for Liquid Line. 3/8" Sweat. Sporlan 6 Digit# 700130 Used on DXM 1-1 (1 needed), DXM 1-2 (1 needed), DXM 1-3 (2 needed), DXM 2-1 (2 needed), DXM 2-2 (2 needed), DXM 3-1 (2 needed).
|
|
|
|
|
|
|
|
|
|
|
Lookup Part! - ALC-066208
|
Liquid Line Solenoid Valve for Carrier 10 and 12.5 ton Dual Circuited Condensers. Also used on 7.5 ton single cuircuit condenser.
|
|
|
|
Lookup Part! - AMG-24/50-60
|
Solenoid Coil for Carrier 10, 12.5, 15 and 20 ton Dual Circuited Condensers. Also used on 7.5 ton single circuit.
|
|
|
|
Lookup Part! - DXM1-3 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM1-3 Coil with installation manual. Fits (10 Ton - 2 Circuit DX Coil, 5EJ0804B-31.5x27.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM1-4 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM1-4 Coil with installation manual. Fits (12.5 Ton - 2 Circuit DX Coil, 5E13804B-31.5x27.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM2-1 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM2-1 Coil with installation manual. Fits (5 Ton - 2 Circuit DX Coil, 5EJ0603B-37.5x36.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM2-2 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM2-2 Coil with installation manual. Fits (10 Ton - 2 Circuit DX Coil, 5EJ0703B-37.5x36.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM2-4 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM2-4 Coil with installation manual. Fits (20 Ton - 2 Circuit DX Coil, 5EJ0904B-37.5x36.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM3-1 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM3-1 Coil with installation manual. Fits (10 Ton - 2 Circuit DX Coil, 5EJ0603B-43.5x42.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM3-2 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM3-2 Coil with installation manual. Fits (15 Ton - 2 Circuit DX Coil, 5EJ0703B-43.5x42.0) 2 fittings included. Installation by others.
|
|
|
Lookup Part! - DXM4-1 HGB kit
|
Hot Gas Bypass Installation Kit for a DXM4-1 Coil with installation manual. Fits (20 Ton - 2 Circuit DX Coil, 5EJ0603B-52.5x48.0) 2 fittings included. Installation by others.
|
|
|
|
|
|
|
Lookup Part! - MPU-AC CONTROL
|
Control Package for Mod Package Unit Cooling Only Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
|
|
|
Lookup Part! - MPU-HP CONTROL
|
Control Package for Mod Package Unit Heat Pump Unit. Includes airflow proving switch, RTUlink-ACHP board and terminal blocks.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Lookup Part! - NC-KEYJB
|
NONVENT Cap key. Works with NONVENT Caps and is required to remove them. Required to unlock 86682 (old# NCP-4) locking condensing unit caps.
|
|
|
|
|
|
|
|
Lookup Part! - S-7061
|
Accumulator for Carrier 10 ton and 12.5 ton, Dual Circuited Condensing Units. 2 parts included.
|
|
|
|
|
Lookup Part! - TXV-ERZE-3-GA-3/8x1/2x1/4
|
Thermal Expansion Valve. R410A. Sporlan 6 digit: 168788 Used on DXM1-1 (1 needed), DXM 2-1 (2 needed) 3 Ton. Also used on MPU1-3 (1 needed), MPU1-5 (1 needed), MPU1-5E (2 needed), MPU2-7.5 (1 needed), and MPU2-8 (1 needed).
|
|
|
Lookup Part! - TXV-ERZE-5-GA-3/8x1/2x1/4
|
Thermal Expansion Valve. R410A. Sporlan 6 digit #: 168792 Used on DXM1-2 (1 needed), DXM1-3 (2 needed), DXM2-2 (2 needed), DXM3-1 (2 needed), 5 Ton. Also used on MPU2-5 (1 needed), MPU 2-7.5 (1 needed), MPU 2-8 ( 1 needed), MPU 2-10 (2 needed) and MPU3-10(2 needed).
|
|
|
|
|
|
|
|
|
|
|